Wall Cooler Automation with Power Saving Feature

⭐ — (0 endorsements) 📥 45 downloads 📅 6/1/2022
⚪ Last updated 2022

By 76561198002587588 · IC Code

⬇ Download Mod Source: Steam Workshop ↗ 📅 Updated: 6/1/2022 📅 Created: 6/1/2022

🔍 Analysis

  • 🏆 #886 of 1087 IC Code mods in this game by downloads

📋 About This Mod

​This code requires: - indoor gas sensor. - as many wall coolers as you want. - one station battery. When the temperature goes above 25C, the wall coolers will turn on, and if it goes below 15C, they will turn off. Before the wall coolers are allowed to turn on, the code also checks the current charge on the battery, and if it is below 1MW, the wall coolers will not be allowed to turn on (and turn off if they are already on) to conserve power. All these values can be adjusted to personal preference in the code. The max temp can be set in line 8 (default 298. 15K (25C)). The min temp can be set in line 9 (default 288. 15K (15C)). The battery charge threshold can be set in line 14 (default 1000000 (1MW)).

📊 Mod Details

Game
Stationeers Mods
Author
76561198002587588
Version
N/A
Downloads
45
Endorsements
0
Category
IC Code
Created
6/1/2022
Updated
6/1/2022

🔧 How to Install Stationeers Mods

Subscribe on Steam Workshop. Mods auto-download and install. Launch the game to activate.

📖 Full step-by-step install guide for Stationeers →

Visit the official mod page for specific installation instructions for this mod.

🎮 Need cheat codes or console commands? Check ur gaming wiki for Stationeers commands, item IDs, and more.

Keep browsing — more Stationeers mods await

📋 All Stationeers Mods 🏆 Top 25 📂 More IC Code 👤 More by 76561198002587588 🔎 Similar Mods 🌐 Best IC Code (All Games) 🔀 Check Compatibility ⚖️ Compare Mods 🆕 New Mods